• A5200TV - Oil Analyzer trivector

    The Model 5200 analyzer trivector combines a range of tests in a single piece of equipment.

    It has an excellent coverage of the three critical areas in the oil analysis - oil quality, system contamination, and machine wear.

    Quality measurements of oil:

    • Dielectric
    • Chemical index
    • Measuring contamination in lubrication system
    • Particle counts in eight sizes
    • ISO codes for either ISO 4406 or ISO 11.171
    • ISO particle count plots
    • Code NAS 1638 and NAS particle counting
    • PC volume with the volume of the PC plot against the size distribution
    • Solids reported as parts per million by volume and size distribution
    • Percentage of water-in-oil
    • Indication of free water
    • Measurements of wear on the machine:
    • Ferrous Index
    • Indication large ferrous
    • Indication large nonferrous


    Besides covering the three areas of oil analysis in a single part of the instrument with ease using the instrument, the CSI has incorporated innovations that carry the most accurate results and diagnostics machine and lubrication problems are easier than before. You will be pleased with the new method of delivering the liquid sample to a laser particle counter that decreases the chances of missing the larger particles as they settle. The analysis of wear debris will be faster and easier with the ability to quickly isolate ferrous particles, non-ferrous, large and small patches separated in the filter. All this is a fundamental building so that the method is well tested and patent CSI to detect the chemical change, in many contaminants ferrous, non-ferrous metals, and liquids. A suitable solvent must be obtained for the sample dilution and cleaning the instrument after each test.

    Standard accessories:

    • Electronic Scale with RS232 interface for the measurement of the dilution ratio
    • Sample pump for extracting samples of non-pressurized systems
    • Polyethylene wash bottle for kerosene distributor or other solvent
    • Glass bowl for 1000 ml of mixed solvents
    • Hand held magnetic retriever with the sleeve to separate particles of ferrous / nonferrous
    • Forceps to hold the patch filter
    • System of waste container:
    • Height 26 in (67.3 cm)
    • Diameter 13 in (33 cm)
    • Weight 12 lbs (5.4 kg)
    • Volume 5 gal (19 liters)
    • Starter kit of consumables
    • Vacuum pump to provide pressure for the removal (specification 110 or 220 volts)
    • Oil View Lite software for instrument operation and data export
  • Back